#!/usr/bin/env bash # 26.03.04 :: klevstul # list all termal zones: # `for i in /sys/class/thermal/thermal_zone*; do echo "$i: $(<$i/type)"; done` # list all temperatures: # `find /sys/devices -name "temp*_input"` # pch_cometlake @ tuxwarrior (i found out by doing more on all tmp input files, and comparing with psensor values): # `/sys/devices/virtual/thermal/thermal_zone3/hwmon6/temp1_input` = `/sys/class/hwmon/hwmon6/temp1_input` threshold=$1 temp_file=$1 threshold=${threshold:=60} temp_file=${temp_file:=/sys/devices/virtual/thermal/thermal_zone3/hwmon6/temp1_input} # the value is reported in milli-degrees celsius. we divide by 1000 to convert to degrees celsius # icon: https://fontawesome.com/icons/temperature-full?f=classic&s=solid # to set colour in svg, set `fill="white"` in the file temperature=$(($(cat ${temp_file}) / 1000)) if [[ ${temperature} -gt ${threshold} ]]; then echo /home/poq/.config/nwg-panel/icons/temperature-full-solid-full.alarm.svg else echo /home/poq/.config/nwg-panel/icons/temperature-full-solid-full.svg fi echo "${temperature}°C"