#!/usr/bin/env bash
# 26.03.04 :: klevstul
# list all termal zones:
# `for i in /sys/class/thermal/thermal_zone*; do echo "$i: $(<$i/type)"; done`
# list all temperatures:
# `find /sys/devices -name "temp*_input"`
# pch_cometlake @ tuxwarrior (i found out by doing more on all tmp input files, and comparing with psensor values):
# `/sys/devices/virtual/thermal/thermal_zone3/hwmon6/temp1_input` = `/sys/class/hwmon/hwmon6/temp1_input`
# the value is reported in milli-degrees celsius. we divide by 1000 to convert to degrees celsius
# icon: https://fontawesome.com/icons/temperature-full?f=classic&s=solid
# to set colour in svg, set `fill="white"` in the file
temperature=$(($(cat /sys/devices/virtual/thermal/thermal_zone3/hwmon6/temp1_input) / 1000))
if [[ ${temperature} -gt 59 ]]; then
echo /home/poq/.config/nwg-panel/icons/temperature-full-solid-full.alarm.svg
echo "WARNING: ${temperature}°C"
else
echo /home/poq/.config/nwg-panel/icons/temperature-full-solid-full.svg
echo "${temperature}°C"
fi